CENTRIFUGAL PUMPS
SPECIFICATION
PUMPS
|
Liquid Handled
|
Type of liquid
|
Clean water
|
Max temperature [°C]
|
60 (CDX 70/05-70/07-90/10)
90
110 (2CDXH and 2CDXHS)
|
Min temperature [°C]
|
-10
|
Maximum working pressure [MPa]
|
0.8
|
Construction
|
Impeller
|
Closed centrifugal type
|
Shaft seal type
|
Mechanical seal
|
Bearing
|
Sealed ball bearing
|
Pipe Connection
|
Suction
|
G 1¼ (G 1½ CDX200)
|
Discharge
|
G 1
|
Material
|
Casing
|
AISI 304
|
Impeller
|
AISI 304
|
Casing cover
|
AISI 304
|
Shaft seal
|
Ceramic/Carbon/NBR (2CDX)
Ceramic/Carbon/FPM (2CDXH)
SiC/SiC/FPM (2CDXHS)
|
Shaft
|
AISI 303 (Wet extension)
|
Bracket
|
Aluminium
|
Applicable standard of test
|
ISO 9906 – Annex A
|
MOTOR
|
Type
|
Electric - TEFC
|
Single Phase
|
Three Phase
|
No. of Poles
|
|
2
|
Rotation speed
|
[min-1]
|
» 2800
|
Insulation Class
|
|
Class F
|
Protection degree
|
|
IP55
|
Power rating
|
[kw]
|
0.75 ÷ 1.5
|
0.75 ÷ 4
|
[HP]
|
1 ÷ 2
|
1 ÷ 5.5
|
Frequency
|
[Hz]
|
50
|
Voltage
|
[V]
|
230 ±10%
|
230/400 ±10%
|
Capacitor
|
|
Built in
|
-
|
Over load protection
|
|
Built in
|
Provided by the user
|
Casing material
|
|
Aluminium
|
Base material/motor support
|
|
Aluminium
|
Dimensions of cable entry
|
|
PG 11, PG 13.5, PG 16 (see dimension page 400)
|
SPECIFICATION

Type pumps
|
Power
|
Q=Capacity
|
[kW]
|
[HP]
|
l/min 20
|
40
|
60
|
80
|
120
|
150
|
180
|
210
|
Single Phase
|
Three Phase
|
2.4
|
3.6
|
4.8
|
7.2
|
9.0
|
10.8
|
12.6
|
2.4
|
H=Total manometric head in meters
|
2CDXM 70/10
|
2CDX 70/10
|
0.75
|
1
|
38.5
|
35.3
|
31.5
|
27
|
-
|
-
|
-
|
-
|
2CDXM 70/12
|
2CDX 70/12
|
0.9
|
1.2
|
44.5
|
40.3
|
35.5
|
30
|
-
|
-
|
-
|
-
|
2CDXM 70/15
|
2CDX 70/15
|
1.1
|
1.5
|
52.5
|
48
|
42.8
|
36.5
|
-
|
-
|
-
|
-
|
2CDXM 70/20
|
2CDX 70/20
|
1.5
|
2
|
60
|
55.6
|
50.4
|
44
|
-
|
-
|
-
|
-
|
2CDXM 120/15
|
2CDX 120/15
|
1.1
|
1.5
|
-
|
42
|
41
|
39.5
|
35
|
30
|
-
|
-
|
2CDXM 120/20
|
2CDX 120/20
|
1.5
|
2
|
-
|
51.5
|
49.5
|
47.4
|
41.8
|
36.5
|
-
|
-
|
-
|
2CDX 120/30
|
2.2
|
3
|
-
|
59
|
57
|
54.6
|
49.2
|
44
|
-
|
-
|
-
|
2CDX 120/40
|
3
|
4
|
-
|
68.5
|
66.5
|
64
|
58
|
52
|
-
|
-
|
-
|
2CDX 200/30
|
2.2
|
3
|
-
|
-
|
52
|
50.8
|
48.1
|
45.5
|
42.7
|
39.5
|
-
|
2CDX 200/40
|
3
|
4
|
-
|
-
|
62.5
|
61.1
|
58
|
55.2
|
52.3
|
49
|
-
|
2CDX 200/50
|
3.7
|
5.5
|
-
|
-
|
71.5
|
70.1
|
67
|
64.3
|
61.2
|
57.5
|
Type key

2CD 70 PERFORMANCE CURVES
2CDX 70/10 (0.75 kW) Impeller diameter = 132/132
2CDX 70/12 (0.90 kW) Impeller diameter = 153/132
2CDX 70/15 (1.10 kW) Impeller diameter = 153/153
2CDX 70/20 (1.50 kW) Impeller diameter = 153/176

Rotation speed: »2800 min-1
Test fluid: clean water at 20°C
Applicable standard of test: ISO 9906 – Annex A
2CD 120 PERFORMANCE CURVES
2CDX 120/15 (1.10 kW) Impeller diameter = 132/132
2CDX 120/20 (1.50 kW) Impeller diameter = 157/132
2CDX 120/30 (2.20 kW) Impeller diameter = 157/157
2CDX 120/40 (3.00 kW) Impeller diameter = 176/157


Rotation speed: »2800 min-1
Test fluid: clean water at 20°C
Applicable standard of test: ISO 9906 – Annex A
2CD 200 PERFORMANCE CURVES
2CDX 200/30 (2.20 kW) Impeller diameter = 157/132
2CDX 200/40 (3.00 kW) Impeller diameter = 157/157
2CDX 200/50 (3.70 kW) Impeller diameter = 176/157

Rotation speed: »2800 min-1
Test fluid: clean water at 20°C
Applicable standard of test: ISO 9906 – Annex A
SECTIONAL VIEW

N°
|
PART NAME
|
MATERIAL
|
Q.TY
|
N°
|
PART NAME
|
MATERIAL
|
Q.TY
|
1
|
Casing
|
AISI 304
|
1
|
26
|
O-ring [3]
|
NBR
|
1
|
3
|
Motor bracket
|
Aluminium (up to 1.5 kW included)
|
1
|
27
|
O-ring [3]
|
NBR
|
1
|
|
|
Cast iron (for 2.2 kW and above)
|
|
32
|
Key
|
AISI 304
|
2
|
4
|
Casing cover
|
AISI 304
|
1
|
34
|
Impeller nut
|
AISI 304
|
1
|
6
|
Shaft with rotor
|
AISI 304 (Part in contact with liquid)
|
1
|
42
|
Motor support
|
Aluminium
|
1
|
7
|
Impeller
|
AISI 304
|
1
|
52
|
Terminal box [1]
|
Polypropilene
|
1
|
8
|
Impeller
|
AISI 304
|
1
|
53
|
Terminal box cover [1]
|
Polypropilene
|
1
|
9
|
Diffuser
|
AISI 304
|
1
|
56
|
Box gasket
|
NBR
|
1
|
11
|
Mechanical seal [3]
|
Ceramic/Carbon/NBR
|
1
|
72
|
Casing ring [3]
|
NBR
|
1
|
12
|
Motor frame with stator
|
-
|
1
|
73
|
Casing ring [3]
|
NBR
|
1
|
13
|
Motor cover
|
Aluminium
|
1
|
75
|
Washer
|
AISI 304
|
1
|
14
|
Fan
|
Polypropilene
|
1
|
76
|
Washer
|
AISI 304
|
1
|
15
|
Fan cover
|
Fe P04 Zinked
|
1
|
77
|
O-ring [3]
|
NBR
|
1
|
16
|
Terminal box
|
-
|
1
|
78
|
O-ring [3]
|
NBR
|
1
|
17
|
Terminal box cover [2]
|
Aluminium
|
1
|
79
|
Space diffuser
|
AISI 304
|
1
|
18
|
Splash ring
|
NBR
|
1
|
90
|
Cover gasket [1]
|
NBR
|
1
|
19
|
Pump side ball bearing
|
-
|
1
|
92
|
Lip seal
|
-
|
1
|
20
|
Fan side ball bearing
|
-
|
1
|
93
|
Lip seal
|
-
|
1
|
21
|
Adjusting ring
|
Steel C70
|
1
|
102
|
Suction cover
|
AISI 304
|
1
|
22
|
Tie rod
|
Fe 42 Zinked
|
4
|
103
|
Conveyor cover
|
AISI 304
|
1
|
23
|
Capacitor [1]
|
-
|
1
|
105
|
Sleeve
|
AISI 304
|
1
|
24
|
Priming plug
|
AISI 303
|
1
|
110
|
Protector [1]
|
-
|
1
|
25
|
Drain plug
|
AISI 303
|
1
|
200
|
Screw
|
Stainless steel A2 UNI7323
|
8
|
- Only for single phase
- Only for three phase
- FPM for 2CDXH and 2CDXHS
MECHANICAL SEAL

REF
|
PART NAME
|
MATERIAL
|
Standard version
(2CDX)
|
Optional
|
(2CDXH)
|
(2CDXHS)
|
A
|
Rotary seal ring
|
Ceramic
|
Ceramic
|
Silicon carbide
|
B
|
Stationary seal ring
|
Carbon graphite
|
Carbon graphite
|
Silicon carbide
|
C
|
O Ring
|
NBR
|
FPM
|
FPM
|
D
|
O Ring
|
NBR
|
FPM
|
FPM
|
E
|
O Ring
|
NBR
|
FPM
|
FPM
|
F
|
Self driving spring
|
AISI 316
|
AISI 316
|
AISI 316
|
G
|
Frame
|
AISI 304
|
AISI 304
|
AISI 316
|
SINGLE PHASE DIAGRAM AND ELECTRIC CONNECTIONS
FOR MOTORS WT ┤ LOCKED ROTOR CURRENT
UP TO 25 [ A ]
( INTERNAL MOTORPROTECTOR )

|
FOR MOTORS WT ┤ LOCKED ROTOR CURRENT
OVER 25 [ A ]
( EXTERNAL MOTORPROTECTOR )

|
PUMP
|
MOTORPROTECTOR
|
INTERNAL
|
EXTERNAL
|
2CDXM 70/10
|
X
|
|
2CDXM 70/12
|
X
|
|
2CDXM 70/15
|
|
X
|
2CDXM 70/20
|
|
X
|
2CDXM 120/15
|
|
X
|
2CDXM 120/20
|
|
X
|
FOR MOTOR 4 kW AND BELOW
Pump type 2CDXM
2CDX
|
Dimensions [mm]
|
A
|
B
|
C
|
D
|
E
|
H
|
H1
|
H2
|
H3
|
H4
|
M
|
M1
|
N
|
N1
|
R
|
T
|
V
|
W
|
S
|
DNA
|
70/10
|
208
|
355
|
169
|
12.5
|
8
|
229
|
106
|
123
|
206
|
210
|
50
|
38
|
120
|
160
|
142.5
|
PG 11
|
PG 11
|
93
|
9
|
G1¼
|
70/12
|
208
|
355
|
169
|
12.5
|
8
|
229
|
106
|
123
|
206
|
231
|
50
|
38
|
120
|
160
|
142.5
|
PG 13.5
|
PG 11
|
93
|
9
|
G1¼
|
70/15
|
232
|
385
|
199
|
12.5
|
8
|
250
|
118
|
132
|
238
|
251
|
55
|
40
|
140
|
180
|
140
|
PG 13.5
|
PG 11
|
95
|
9
|
G1¼
|
70/20
|
232
|
385
|
199
|
12.5
|
8
|
250
|
118
|
132
|
238
|
251
|
55
|
40
|
140
|
180
|
140
|
PG 13.5
|
PG 11
|
95
|
9
|
G1¼
|
120/15
|
208
|
380
|
199
|
12.5
|
8
|
229
|
106
|
123
|
226
|
239
|
55
|
40
|
140
|
180
|
140
|
PG 13.5
|
PG 11
|
95
|
9
|
G1¼
|
120/20
|
208
|
380
|
199
|
12.5
|
8
|
229
|
106
|
123
|
226
|
239
|
55
|
40
|
140
|
180
|
140
|
PG 13.5
|
PG 11
|
95
|
9
|
G1¼
|
120/30
|
232
|
393
|
210
|
12.5
|
8
|
250
|
118
|
132
|
242
|
-
|
65
|
40
|
140
|
180
|
144
|
-
|
PG 13.5
|
109
|
9
|
G1¼
|
120/40
|
232
|
394
|
210
|
12.5
|
8
|
250
|
118
|
132
|
242
|
-
|
65
|
40
|
140
|
180
|
144
|
-
|
PG 13.5
|
109
|
9
|
G1¼
|
200/30
|
208
|
394
|
210
|
12.5
|
8
|
229
|
106
|
123
|
230
|
-
|
65
|
40
|
140
|
180
|
144
|
-
|
PG 13.5
|
109
|
9
|
G1½
|
200/40
|
232
|
394
|
210
|
12.5
|
8
|
250
|
118
|
132
|
242
|
-
|
65
|
40
|
140
|
180
|
144
|
-
|
PG 13.5
|
109
|
9
|
G1½
|
200/50
|
232
|
450
|
236
|
16
|
13
|
250
|
118
|
132
|
255
|
-
|
68
|
50
|
160
|
210
|
144
|
-
|
PG 16
|
109
|
12
|
G1½
|
PACKING AND WEIGHT

Type pumps
|
PACKING [mm]
|
WEIGHT [kg]
|
Single Phase
|
Three Phase
|
X
|
Y
|
Z
|
Single
Phase
|
Three
Phase
|
2CDXM 70/10
|
2CDX 70/10
|
255
|
300
|
367
|
13.5
|
13.3
|
2CDXM 70/12
|
2CDX 70/12
|
255
|
300
|
367
|
14.2
|
13.8
|
2CDXM 70/15
|
2CDX 70/15
|
255
|
300
|
397
|
17.4
|
16.4
|
2CDXM 70/20
|
2CDX 70/20
|
255
|
300
|
397
|
18.6
|
18.2
|
2CDXM 120/15
|
2CDX 120/15
|
255
|
300
|
397
|
15.5
|
15.3
|
2CDXM 120/20
|
2CDX 120/20
|
247
|
300
|
397
|
18
|
16.9
|
-
|
2CDX 120/30
|
252
|
300
|
457
|
-
|
23.2
|
-
|
2CDX 120/40
|
252
|
300
|
457
|
-
|
26.4
|
-
|
2CDX 200/30
|
239
|
300
|
457
|
-
|
25
|
-
|
2CDX 200/40
|
239
|
300
|
457
|
-
|
25
|
-
|
2CDX 200/50
|
247
|
300
|
457
|
-
|
32.7
|
Type pumps
|
kW
|
HP
|
Ball Bearing
|
Capacitor
Single Phase
|
Input
in [kW]
|
Full load current
in [A]
|
Ball Bearing
|
|
Single Phase 230 V
50 Hz
|
Three Phase 230/400 V
50 Hz
|
Pump side
|
Fan side
|
F
|
Vc
|
Single Phase
|
Three Phase
|
Single Phase
|
Three Phase
|
|
230 V
|
400
400 V
|
|
2CDXM 70/10
|
2CDX 70/10
|
0,75
|
1
|
6203 ZZ
|
6202 ZZ
|
20
|
450
|
1,30
|
1,18
|
6,0
|
4,0
|
2,3
|
|
2CDXM 70/12
|
2CDX 70/12
|
0,9
|
1,2
|
6203 ZZ
|
6202 ZZ
|
31,5
|
450
|
1,50
|
1,50
|
7,0
|
5,0
|
2,9
|
|
2CDXM 70/15
|
2CDX 70/15
|
1,1
|
1,5
|
6204 ZZ
|
6203 ZZ
|
35
|
450
|
1,80
|
1,64
|
8,0
|
5,6
|
3,2
|
|
2CDXM 70/20
|
2CDX 70/20
|
1,5
|
2
|
6204 ZZ
|
6203 ZZ
|
40
|
450
|
2,30
|
2,20
|
9,9
|
7,0
|
4,0
|
|
2CDXM 120/15
|
2CDX 120/15
|
1,1
|
1,5
|
6204 ZZ
|
6203 ZZ
|
35
|
450
|
1,80
|
1,70
|
8,3
|
5,6
|
3,2
|
|
2CDXM 120/20
|
2CDX 120/20
|
1,5
|
2
|
6204 ZZ
|
6203 ZZ
|
40
|
450
|
2,35
|
2,20
|
10,2
|
7,0
|
4,0
|
|
-
|
2CDX 120/30
|
2,2
|
3
|
6305 ZZ
|
6205 ZZ
|
-
|
-
|
-
|
2,85
|
-
|
8,7
|
5,0
|
|
-
|
2CDX 120/40
|
3
|
4
|
6305 ZZ
|
6205 ZZ
|
-
|
-
|
-
|
3,50
|
-
|
10,8
|
6,2
|
|
-
|
2CDX 200/30
|
2,2
|
3
|
6205 ZZ
|
6205 ZZ
|
-
|
-
|
-
|
3,05
|
-
|
10,4
|
6,0
|
|
-
|
2CDX 200/40
|
3
|
4
|
6305 ZZ
|
6205 ZZ
|
-
|
-
|
-
|
3,85
|
-
|
11,4
|
6,6
|
|
-
|
2CDX 200/50
|
3,7
|
5
|
6206 ZZ
|
6205 ZZ
|
-
|
-
|
-
|
4,60
|
-
|
15,0
|
8,7
|
|
Type pumps
|
Locked rotor current
|
Single Phase
230 V
50 Hz
|
Three Phase
230/400 V
50 Hz
|
Single Phase
230 V
50 Hz
|
Three Phase
|
230 V
50 Hz
|
400 V
50 Hz
|
2CDXM 70/10
|
2CDX 70/10
|
22.7
|
24.1
|
13.9
|
2CDXM 70/12
|
2CDX 70/12
|
25.5
|
28.2
|
16.3
|
2CDXM 70/15
|
2CDX 70/15
|
39
|
29.4
|
17
|
2CDXM 70/20
|
2CDX 70/20
|
43
|
45
|
26
|
2CDXM 120/15
|
2CDX 120/15
|
39
|
29.4
|
17
|
2CDXM 120/20
|
2CDX 120/20
|
43
|
45
|
26
|
-
|
2CDX 120/30
|
-
|
58.9
|
34
|
-
|
2CDX 120/40
|
-
|
84.9
|
49
|
-
|
2CDX 200/30
|
-
|
84.9
|
49
|
-
|
2CDX 200/40
|
-
|
84.9
|
49
|
-
|
2CDX 200/50
|
-
|
132.7
|
76.6
|
|